New Products - FANN®

Lost Circulation Material Evaluation Receiver

Lost Circulation Material Receiver (LCM)The Lost Circulation Material (LCM) Evaluation Receiver is an alternative back pressure receiver for the Fann® Permeability Plugging Apparatus (PPA) and Automated Plugging Apparatus (APPA).

The LCM Evaluation Receiver can handle larger particles without plugging. This new design is beneficial for testing drilling fluids containing various sized material at engineered concentrations.

These special drilling fluids seal multiple lost circulation situations, including severe fluid losses.

Advantages

  • Custom built for testing LCM fluids with large particle sizes
  • Larger orifice to help prevent plugging
  • Cell cap (included) that easily installs into Fann PPA and APPA

 

Specifications
 Volume 178 ml
Orifice Size  7 mm (0.28 in) 
Dimensions
(length x diameter) 

16 x 3 inches
41 x 7.6 centimeters 

 Weight 3.85 kg (8.5 lb) 

 

Ordering Information

Part No. 102308743 -- Lost Circulation Material Evaluation Receiver

Stainless Steel Slotted Discs are available in various slot types and sizes.  These discs are recommended for testing LCM fluids containing larger particle sizes.

 

Filter By  
Show     results per page
  Title  Date Date Date Date selections - Creation Date Date selections - Last Update
Summary Lost Circulation Material Receiver and Tester
Instruction Manual for Lost Circulation Material Receiver and Tester (LCM)
2014-10-01T01:00:00.000-05:00 2018-04-11T02:24:56.773-05:00 2018-04-06T06:27:07.421-05:00
Summary Lost Circulation Material Receiver and Evaluator - with Vug Adapter
Instruction Manual for Lost Circulation Material Receiver and Tester (LCM) with Vug adapter.
2016-08-25T01:00:00.000-05:00 2018-04-11T02:24:50.918-05:00 2018-04-06T06:27:07.421-05:00
Summary Lost Circulation Material Evaluation Receiver
LCM Lost Circulation Material receiver
2014-08-15T01:00:00.000-05:00 2018-04-11T02:26:43.278-05:00 2018-04-06T06:27:38.588-05:00
Summary Lost Circulation Material Evaluation Receiver (LCM) Vug Adapter
Vug adapter for the LCM.
2016-08-25T01:00:00.000-05:00 2018-04-11T02:27:11.353-05:00 2018-04-06T06:27:38.588-05:00
Summary Ceramic Filters
Ceraminc disc filters for PPA and HPHT Filtration Units
2016-01-11T00:00:00.000-06:00 2018-04-11T02:26:28.149-05:00 2018-04-06T06:27:36.886-05:00
Summary Slotted Discs for LCM Evaluation
LCM Lost Circulation Material receiver slotted disks
2014-08-15T01:00:00.000-05:00 2018-04-11T02:27:07.314-05:00 2018-04-06T06:27:38.588-05:00
Summary Lost Circulation Material Evaluation Receiver
Lost Circulation Material Evaluation Receiver for Permeability Plugging Apparatus (PPA) and Automated Plugging Apparatus (APPA)
2014-08-15T01:00:00.000-06:00 2018-04-06T00:58:43.618-05:00
Related Information